APPX 4.0.3 Patch |
Patches 0LA |
7/9/99 |
Requirements
This patch can only be applied to release 4.0.2 of the APPX 0LA application. Verify that 0LA is release 4.0.2 by examining the release number as follows:
In, 3-System Administration | 3-Database/Applications | 1-Applications, select the application 0LA/00 and press Enter. On the popup window the release number 4.0.2 should be visible in the title bar.
Problem Description, ECR #4780
Pressing SCAN from within Scan's, "Select File" or "Select Path" processes would result in an infinite loop.
Patch Instructions
This patch is a patch to the APPX 0LA application. Make sure that you have a backup of your appx/data/00/0LA directory.
1) On your system an empty application 1LA/00.
2) Retrieve one of the following patch files
ftp://ftp.appx.com/pub/0apatch/403-int.tgz for intel systems
ftp://ftp.appx.com/pub/0apatch/403-ris.tgz for risc systems
This contains Data and Struct directories for the 1LA app. Explode this file into your appx/data directory. It should overlay the application that you created in step 1
3) From design file management for 0LA/00, choose 14-Apply Patch with Design Transfer. Enter 1LA/00 as the From Application and press Enter twice to do the transfer. It should automatically process the DD for 0LA.